Outdoor Battery Cabinet, IP55

There is nowhere indoors to put a battery. The plant room is full, the switchgear room has no space left, and the yard already has a pad or room for one.

The cabinet stands outside, connects to the board that exists, and leaves the plant room alone.

IP55 cabinet, IP66 inverterC4 standard, C5 optional1349 × 2100 × 990 mm1,025–1,303 kg
DEFINITION

One Enclosure Outdoors Replaces the Room You Do Not Have

An outdoor battery cabinet is a weather-protected enclosure holding the battery, the conversion and the transfer switch, standing on a foundation outside the building. It replaces the plant room, the container and the room cooling an indoor unit needs, and it frees floor space inside the building.

RATINGS

IP55 Outside, IP66 at the Inverter

IP55 covers dust and water jets from any direction, which is what a yard delivers in rain, washdown and grit. IP66 at the inverter adds stronger jets. Neither is a submersion rating.

Water goes where the pad and the glands send it. Entries are glanded, and the door seal is checked at each service.

CIVIL WORKS

What the Site Builds Before the Cabinet Arrives

  • A level pad sized to the cabinet and its lifting clearance.
  • A trench for the AC cable to your switchgear.
  • An earth connection to the site bar.

Clearances and cable entry are confirmed at the site check, since the door swing and fence line decide them. Those three lines sit outside the cabinet scope.

HOW TO JUDGE IT

Six Questions to Ask About Any Outdoor Cabinet

Dust and salt air do not fail a cabinet in one event. They fail it over three or four years, at the joints, the glands and the electronics. These are the questions that separate a cabinet built for a yard from a cabinet that happens to be standing in one.

1. What is the inverter's own IP rating?

Vague answer: a single cabinet figure, quoted as if it covered the electronics. Our answer: IP66 at the inverter, IP55 for the cabinet. The two numbers are not interchangeable, and a cabinet rating says nothing about what is inside it.

2. Does cooling air pass over the boards?

Vague answer: "air cooled", with no detail about where the air goes. Our answer: the inverter is a sealed IP66 unit; heat leaves through an aluminium-nitride heatsink into its own duct, not through the electronics.

3. Does inverter heat reach the battery compartment?

Vague answer: one fan, one chamber, warm air shared by everything. Our answer: two independent air paths, one for the power stage and one for the battery, separated by rock-wool insulation.

4. What corrosion class, and is it optional?

Vague answer: "anti-corrosion coating", with no class. Our answer: C4 as standard, C5 optional. Within 1 km of the coast, quote C5; 1–10 km, C4.

5. What humidity is it rated for, and does it condense?

Vague answer: a number without "non-condensing". Our answer: 0–95% RH, non-condensing. The cabinet is not a dehumidifier: standing water, blocked drains and trapped air above the pad still cause failures.

6. What happens at 45 °C in the shade?

Vague answer: "up to 55 °C", without saying whether output drops. Our answer: full power at 45 °C ambient without derating; the working range is −20 to +55 °C.

The questions are worth asking of any supplier, including us. A datasheet that answers all six in writing is a better datasheet than one that answers none.

CORROSION

Coast Sites Take the C5 Option

Corrosion protection is C4 as standard, which suits most inland industrial sites. C5 is the option for coastal air and for chemical plants.

The choice comes from the location and the process. Getting it wrong shows up years later as a door seal that no longer seats.

SITING

Heat Is Settled by Where the Cabinet Stands

A cabinet in the open takes its air from the yard, and the space around it decides how well that works. A wall on one side, a fence on another and full afternoon sun leave less room than a clear stand does.

The site's temperature record goes into the design, and the position is adjusted before the pad is poured. A yard that runs hot in August asks more of any enclosure than one with shade.

DELIVERY

It Arrives on a Trailer, Not in a Container

At 1,025 to 1,303 kg, the cabinet travels on a standard trailer and comes off with a crane or a heavy forklift. It arrives assembled, so unloading is one lift.

It ships at 30% state of charge or less, documents follow within 15 days, and spares sit in the EU, South Africa, Pakistan and Brazil. Certificates are CB IEC 62619, CB IEC 63056 and CEI 0-21; UL 9540 and NFPA 855 are not held.

FAQ

Questions about outdoor battery cabinet

Can it stand in the rain?

Yes. The cabinet is IP55 and the inverter inside is IP66, so rain and washdown are within the rating. It stands on a raised pad with glanded entries. IP55 is not a submersion rating, so a flooding site needs a higher pad.

What about salt spray at a coastal site?

Take the C5 option. C4 is standard and suits most inland sites; C5 is specified for coastal air and chemical plants. Tell us the distance to the coast and what the plant handles on site, and the specification follows from that.

Does it need a foundation?

A level concrete pad sized to the cabinet and its lifting clearance, a trench for the AC cable, and an earth connection. Those three lines are on your side of the scope, and the pad needs to cure before delivery day.

Does output drop in summer?

The cabinet is rated at a reference ambient, and cooling comes from its own unit. Where the site runs hotter, placement and the temperature record shape the design. A yard that runs hot in August gets a different position from one with shade and a breeze.

A Photo of the Yard Gets the Pad Drawing Back.

A photo, the distance to the switchgear and a recent bill. You get the cabinet position, the pad size and the cable route.