CabESSLuminBlock H · C&I all-in-one hybrid ESS
Home / Battery Storage Glossary
Reference · A to Z

Battery Storage Glossary

Thirty terms that turn up in quotes, datasheets and grid applications, written in the language of a site meeting rather than a standards committee.

Each entry is one or two sentences. Where a number helps, the number is there.

30 terms90% usable energy88% round-trip efficiency10 ms backup transfer
A–C

A to C

A working glossary for this site: BESS and ESS, kW against kWh, depth of discharge, state of health, round-trip efficiency, MPPT, static transfer switch and commercial and industrial. Each entry is one or two sentences, written so a buyer can check the term against a quote or a datasheet.

TermWhat it means
AC couplingThe battery connects on the AC side of an existing solar inverter, so the PV system stays as it is.
AFCIArc fault circuit interrupter. It detects a damaged DC conductor before it becomes a fire.
All-in-oneOne enclosure holding inverter, battery, cooling and fire suppression, wired and tested at the factory.
BESSBattery energy storage system. The whole assembly, including the cells.
BMSBattery management system. It watches cell voltage and temperature and stops the pack outside its limits.
CB certificateAn IECEE test report that a national body can convert into its own approval. It is not a grid approval on its own.
C–D

C to D

TermWhat it means
CEI 0-21The Italian grid connection standard for low voltage storage. It is the grid certificate held for this product.
C-rateCharge or discharge current relative to capacity. 0.5C on a 120 kWh cabinet is 60 kW.
DC couplingThe battery shares a DC bus with the PV array, usually through one hybrid inverter.
Demand chargeA monthly charge based on the highest power you draw. Shaving that peak is a common storage case.
DoDDepth of discharge. This cabinet uses 90%, so 120 kWh nameplate gives 108 kWh usable.
Diesel hybridA battery and a diesel set running in parallel, with the transfer switch inside the cabinet.
E–I

E to I

TermWhat it means
EMSEnergy management system. The controller that decides when the battery charges, discharges or waits.
Essential boardThe sub-panel that stays live during an outage, carrying only the circuits you chose.
Hybrid inverterAn inverter that manages PV, battery and grid together rather than only one of them.
IEC 62619The safety standard for industrial lithium cells and batteries, held here as CB IEC 62619:2022.
IEC 63056The safety standard for secondary batteries used in electrical energy storage, held as CB IEC 63056.
IP55Ingress protection. Dust protected and resistant to water jets, which suits outdoor cabinets.
I–P

I to P

TermWhat it means
Island modeRunning the site without the grid. Load ratios apply to motor and transformer loads.
kW and kWhPower and energy. kW is what the battery can carry now, kWh is how long it can carry it.
LFPLithium iron phosphate, the cell chemistry used here. 314 Ah cells, chosen for cycle life and stability.
MPPTMaximum power point tracker. Five inputs per cabinet, so mixed roof orientations stay on separate strings.
Parallel operationSeveral cabinets sharing load through a controller. Ten units reach 600 kW and 4,800 kWh.
Peak shavingCutting the highest half-hourly draw to reduce the demand charge, without reducing site work.
P–U

P to U

TermWhat it means
Power factorThe ratio of real to apparent power. Correction avoids utility penalties on inductive loads.
Power storage batteryAnother name for a battery that stores grid or PV energy for later use. The specification - power, energy, chemistry - matters more than the label.
Round-trip efficiencyEnergy out divided by energy in. Here 88% from AC to AC.
SOCState of charge. Cabinets ship at or below 30% for transport, and storage above six months needs a top-up.
SOHState of health. Capacity remaining as a share of the original. The warranty floor is 70%.
String-level shutdownIsolating one PV string without stopping the array, which keeps the rest generating during service.
UL 9540A North American safety standard for energy storage systems. It is not held for this product, so US and Canadian projects need another route.
Power storage battery costDriven by usable kWh, inverter size and the metering around it — not by the cells alone. Ask for the scope, not a per-kWh figure.
Large power storage batteryAt this site, the largest single unit is 120 kWh; systems scale to 4.8 MWh by paralleling ten cabinets and adding DC cabinets.
FAQ

Questions about battery storage glossary

What does usable energy mean?

Nameplate energy times depth of discharge. A 120 kWh cabinet gives 108 kWh at 90% DoD.

Is a CB certificate enough for my utility?

Usually not on its own. The utility or national body converts it, and that filing is separate work.

Why does kW matter as much as kWh?

A full battery behind a small inverter cannot carry a large load. Power and energy are chosen separately.

Ask About the Term You Keep Hearing

Start with the form. Our sales team asks for the sentence from the quote or the datasheet. The reply explains it in the same plain terms as this page.