Two Shifts, and a Demand That Never Drops
Moulding and assembly run through both shifts. Demand stays high until late evening, and production targets keep rising. The site buys power on an industrial tariff with a demand component, so the shape of the load matters as much as the total.
- Load shape: high and long, with sudden steps when equipment starts.
- Cost driver: the monthly peak, not the annual total.
- Constraint: the contracted grid capacity.
What the Meter Records, and Why It Costs Money
Demand charges scale with the highest fifteen-minute peaks each month. Sudden starts push consumption above the contracted capacity. Cheap overnight power cannot be used during the next day's shift, and rising production increases exposure to volatile industrial tariffs.
The plant did not need more energy. It needed to move cheap energy into expensive hours and stop the peaks from setting the bill.
Five Cabinets Working as One Plant
Five 125 kW / 261 kWh cabinets combine into 625 kW of conversion capacity and 1,305 kWh of stored energy, sized to the plant's peak-shaving demand. They charge when night tariffs are lowest and discharge through the morning and afternoon peaks, holding site demand below the contracted level.
A site energy management system monitors load and state of charge and adjusts dispatch as production changes.
| Parameter | Specification |
|---|---|
| System capacity | 625 kW PCS, 1,305 kWh storage |
| Core products | LuminBlock BESS, BES-P125X261E/U |
| Device list | 5 × 125 kW / 261 kWh cabinets |
| Operation mode | Grid-tied peak shaving and load shifting |
| Key functions | Peak shaving, time-of-use dispatch, frequency regulation, site monitoring |
The Benefits as Claimed on the Source Page
These figures are the manufacturer's, not a measurement by us. Read them as the shape of the case, not a promise for another site.
- Cost reduction — cuts annual electricity spend by about USD 46,500, as stated by the manufacturer.
- Peak shaving — caps the plant's demand peaks with stored energy.
- Time-of-use optimisation — charges on cheap night tariffs, discharges at expensive hours.
- Demand charge reduction — trims the peak that sets monthly grid charges.
- Frequency regulation — adjusts active power quickly to support local grid stability.
What Would Change With a 37.5–60 kW Cabinet
A 625 kW plant is roughly ten H60X120 cabinets in parallel, at the system limit of ten units. That is the same architecture at a smaller unit size: the cabinets would be grouped at the main low-voltage board, with one master and nine slaves, and dispatched by one controller.
- Sizing input: the 15-minute load profile and the contracted capacity, not the annual kWh.
- Duration: the H cabinet holds 72–108 kWh usable per unit, so the discharge window is decided by how many cabinets the peak-shaving target needs.
- Backup: the H cabinet also carries a transfer switch, so essential loads could be moved to the backup port — this project's scope was peak shaving only.
- Limit: ten cabinets, 600 kW / 4.8 MWh, is the system ceiling. A site that needs more is a different product.
Questions about these projects
Is this a LuminBlock H installation?
No. It uses five LuminBlock 125 kW / 261 kWh cabinets, a larger product from the same manufacturer. We describe it because the sizing method and the tariff logic are the same, and because it is a real deployment rather than a hypothetical example.
Where do these figures come from?
From the manufacturer's published account of this deployment. They are the manufacturer's figures, not measurements we took, and every number on this page is attributed to them. The page is self-contained; if you want the original document, ask and we will send it with the quote.
What would the H version of this project look like?
Roughly ten H60X120 cabinets on a low-voltage board, dispatched as one system to cap the same peaks. Peak shaving on the H cabinet needs the 15-minute profile, the contracted capacity and the tariff windows — the same three inputs as the larger plant, at a smaller unit size.